Amusement Logic is currently developing a water park project in which it is implementing its forced aeration dechlorination treatment system. With this system we achieve:

Reuse of water from filter washing in the irrigation of the water park.

Avoiding overloads in the sewage network due to flows from filter washing.

The treatment proposed for this water park project includes two phases:

– 1) Decanting of water from filter washing, carried out in a covered decanter tank with several chambers, with a capacity of 150 m3, in which the water remains for several days, until the sedimentation of particles of one hundredth of a mm.

– 2) Declorination by means of a forced aeration process, carried out in a pool made up of 3 basins adapted to the topography of the site, with a total volume of 260 m3, with which we reduce the necessary treatment time.

On the other hand, and given the heavy rainfall conditions in the area where the water park is located during certain times of the year, the pool also serves as a flood control element, and facilitates the subsequent collection of runoff water in the rainwater network.

By Luis Llor, Head of Hydraulics in the Architecture Department at Amusement Logic